aboutsummaryrefslogtreecommitdiff
path: root/drivers/power
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/power')
-rw-r--r--drivers/power/ab8500_fg.c41
1 files changed, 27 insertions, 14 deletions
diff --git a/drivers/power/ab8500_fg.c b/drivers/power/ab8500_fg.c
index cd03549b622..a0cbbd393fc 100644
--- a/drivers/power/ab8500_fg.c
+++ b/drivers/power/ab8500_fg.c
@@ -43,7 +43,7 @@
#define NBR_AVG_SAMPLES 20
-#define LOW_BAT_CHECK_INTERVAL (2 * HZ)
+#define LOW_BAT_CHECK_INTERVAL (HZ / 16) /* 62.5 ms */
#define VALID_CAPACITY_SEC (45 * 60) /* 45 minutes */
#define BATT_OK_MIN 2360 /* mV */
@@ -169,6 +169,7 @@ struct inst_curr_result_list {
* @recovery_cnt: Counter for recovery mode
* @high_curr_cnt: Counter for high current mode
* @init_cnt: Counter for init mode
+ * @low_bat_cnt Counter for number of consecutive low battery measures
* @nbr_cceoc_irq_cnt Counter for number of CCEOC irqs received since enabled
* @recovery_needed: Indicate if recovery is needed
* @high_curr_mode: Indicate if we're in high current mode
@@ -210,6 +211,7 @@ struct ab8500_fg {
int recovery_cnt;
int high_curr_cnt;
int init_cnt;
+ int low_bat_cnt;
int nbr_cceoc_irq_cnt;
bool recovery_needed;
bool high_curr_mode;
@@ -1879,25 +1881,29 @@ static void ab8500_fg_low_bat_work(struct work_struct *work)
/* Check if LOW_BAT still fulfilled */
if (vbat < di->bm->fg_params->lowbat_threshold) {
- di->flags.low_bat = true;
- dev_warn(di->dev, "Battery voltage still LOW\n");
-
- /*
- * We need to re-schedule this check to be able to detect
- * if the voltage increases again during charging
- */
- queue_delayed_work(di->fg_wq, &di->fg_low_bat_work,
- round_jiffies(LOW_BAT_CHECK_INTERVAL));
+ /* Is it time to shut down? */
+ if (di->low_bat_cnt < 1) {
+ di->flags.low_bat = true;
+ dev_warn(di->dev, "Shut down pending...\n");
+ } else {
+ /*
+ * Else we need to re-schedule this check to be able to detect
+ * if the voltage increases again during charging or
+ * due to decreasing load.
+ */
+ di->low_bat_cnt--;
+ dev_warn(di->dev, "Battery voltage still LOW\n");
+ queue_delayed_work(di->fg_wq, &di->fg_low_bat_work,
+ round_jiffies(LOW_BAT_CHECK_INTERVAL));
+ }
} else {
- di->flags.low_bat = false;
+ di->flags.low_bat_delay = false;
+ di->low_bat_cnt = 10;
dev_warn(di->dev, "Battery voltage OK again\n");
}
/* This is needed to dispatch LOW_BAT */
ab8500_fg_check_capacity_limits(di, false);
-
- /* Set this flag to check if LOW_BAT IRQ still occurs */
- di->flags.low_bat_delay = false;
}
/**
@@ -2056,6 +2062,7 @@ static irqreturn_t ab8500_fg_lowbatf_handler(int irq, void *_di)
{
struct ab8500_fg *di = _di;
+ /* Initiate handling in ab8500_fg_low_bat_work() if not already initiated. */
if (!di->flags.low_bat_delay) {
dev_warn(di->dev, "Battery voltage is below LOW threshold\n");
di->flags.low_bat_delay = true;
@@ -2698,6 +2705,12 @@ static int ab8500_fg_probe(struct platform_device *pdev)
INIT_DEFERRABLE_WORK(&di->fg_check_hw_failure_work,
ab8500_fg_check_hw_failure_work);
+ /* Reset battery low voltage flag */
+ di->flags.low_bat = false;
+
+ /* Initialize low battery counter */
+ di->low_bat_cnt = 10;
+
/* Initialize OVV, and other registers */
ret = ab8500_fg_init_hw_registers(di);
if (ret) {