thermal: cpu_cooling: fix return value check in cpufreq_cooling_register()

In case of error, the function thermal_cooling_device_register() returns
ERR_PTR() and never returns NULL. The NULL test in the return value check
should be replaced with IS_ERR().

Signed-off-by: Wei Yongjun <yongjun_wei@trendmicro.com.cn>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
(cherry picked from commit 73b9bcd76d13716cc0e0ab053f8c1ae41f47636e)
Signed-off-by: Alex Shi <alex.shi@linaro.org>

Conflicts:
	drivers/thermal/cpu_cooling.c
diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c
index dc50315..8c15474 100644
--- a/drivers/thermal/cpu_cooling.c
+++ b/drivers/thermal/cpu_cooling.c
@@ -482,7 +482,7 @@
 	if (IS_ERR(cool_dev)) {
 		release_idr(&cpufreq_idr, cpufreq_dev->id);
 		kfree(cpufreq_dev);
-		return ERR_PTR(-EINVAL);
+		return cool_dev;
 	}
 	cpufreq_dev->cool_dev = cool_dev;
 	cpufreq_dev->cpufreq_state = 0;