regulator: as3722: detect SD0 low-voltage mode

SD0 may operate in low-voltage mode, with a minimum of 0.41V
and a maximum of 1.5V.  This is indicated by bit 4 of FUSE7.

Signed-off-by: Andrew Bresticker <abrestic@chromium.org>
Signed-off-by: Vince Hsu <vinceh@nvidia.com>
broonie.e6264@m.evernote.com
Signed-off-by: Mark Brown <broonie@linaro.org>
diff --git a/drivers/regulator/as3722-regulator.c b/drivers/regulator/as3722-regulator.c
index fdb3137..3d7fbc2 100644
--- a/drivers/regulator/as3722-regulator.c
+++ b/drivers/regulator/as3722-regulator.c
@@ -99,7 +99,6 @@
 		.sleep_ctrl_mask = AS3722_SD0_EXT_ENABLE_MASK,
 		.control_reg = AS3722_SD0_CONTROL_REG,
 		.mode_mask = AS3722_SD0_MODE_FAST,
-		.n_voltages = AS3722_SD0_VSEL_MAX + 1,
 	},
 	{
 		.regulator_id = AS3722_REGULATOR_ID_SD1,
@@ -112,7 +111,6 @@
 		.sleep_ctrl_mask = AS3722_SD1_EXT_ENABLE_MASK,
 		.control_reg = AS3722_SD1_CONTROL_REG,
 		.mode_mask = AS3722_SD1_MODE_FAST,
-		.n_voltages = AS3722_SD0_VSEL_MAX + 1,
 	},
 	{
 		.regulator_id = AS3722_REGULATOR_ID_SD2,
@@ -181,7 +179,6 @@
 		.sleep_ctrl_mask = AS3722_SD6_EXT_ENABLE_MASK,
 		.control_reg = AS3722_SD6_CONTROL_REG,
 		.mode_mask = AS3722_SD6_MODE_FAST,
-		.n_voltages = AS3722_SD0_VSEL_MAX + 1,
 	},
 	{
 		.regulator_id = AS3722_REGULATOR_ID_LDO0,
@@ -595,6 +592,22 @@
 	return as3722_update_bits(as3722, reg, mask, val);
 }
 
+static bool as3722_sd0_is_low_voltage(struct as3722_regulators *as3722_regs)
+{
+	int err;
+	unsigned val;
+
+	err = as3722_read(as3722_regs->as3722, AS3722_FUSE7_REG, &val);
+	if (err < 0) {
+		dev_err(as3722_regs->dev, "Reg 0x%02x read failed: %d\n",
+			AS3722_FUSE7_REG, err);
+		return false;
+	}
+	if (val & AS3722_FUSE7_SD0_LOW_VOLTAGE)
+		return true;
+	return false;
+}
+
 static const struct regulator_linear_range as3722_sd2345_ranges[] = {
 	REGULATOR_LINEAR_RANGE(612500, 0x01, 0x40, 12500),
 	REGULATOR_LINEAR_RANGE(1425000, 0x41, 0x70, 25000),
@@ -820,7 +833,16 @@
 				ops = &as3722_sd016_extcntrl_ops;
 			else
 				ops = &as3722_sd016_ops;
-			as3722_regs->desc[id].min_uV = 610000;
+			if (id == AS3722_REGULATOR_ID_SD0 &&
+			    as3722_sd0_is_low_voltage(as3722_regs)) {
+				as3722_regs->desc[id].n_voltages =
+					AS3722_SD0_VSEL_LOW_VOL_MAX + 1;
+				as3722_regs->desc[id].min_uV = 410000;
+			} else {
+				as3722_regs->desc[id].n_voltages =
+					AS3722_SD0_VSEL_MAX + 1,
+				as3722_regs->desc[id].min_uV = 610000;
+			}
 			as3722_regs->desc[id].uV_step = 10000;
 			as3722_regs->desc[id].linear_min_sel = 1;
 			break;