diff options
Diffstat (limited to 'Documentation/hwmon/ibmpowernv')
-rw-r--r-- | Documentation/hwmon/ibmpowernv | 80 |
1 files changed, 0 insertions, 80 deletions
diff --git a/Documentation/hwmon/ibmpowernv b/Documentation/hwmon/ibmpowernv deleted file mode 100644 index 56468258711f..000000000000 --- a/Documentation/hwmon/ibmpowernv +++ /dev/null @@ -1,80 +0,0 @@ -Kernel Driver IBMPOWERNV -======================== - -Supported systems: - * Any recent IBM P servers based on POWERNV platform - -Author: Neelesh Gupta - -Description ------------ - -This driver implements reading the platform sensors data like temperature/fan/ -voltage/power for 'POWERNV' platform. - -The driver uses the platform device infrastructure. It probes the device tree -for sensor devices during the __init phase and registers them with the 'hwmon'. -'hwmon' populates the 'sysfs' tree having attribute files, each for a given -sensor type and its attribute data. - -All the nodes in the DT appear under "/ibm,opal/sensors" and each valid node in -the DT maps to an attribute file in 'sysfs'. The node exports unique 'sensor-id' -which the driver uses to make an OPAL call to the firmware. - -Usage notes ------------ -The driver is built statically with the kernel by enabling the config -CONFIG_SENSORS_IBMPOWERNV. It can also be built as module 'ibmpowernv'. - -Sysfs attributes ----------------- - -fanX_input Measured RPM value. -fanX_min Threshold RPM for alert generation. -fanX_fault 0: No fail condition - 1: Failing fan - -tempX_input Measured ambient temperature. -tempX_max Threshold ambient temperature for alert generation. -tempX_highest Historical maximum temperature -tempX_lowest Historical minimum temperature -tempX_enable Enable/disable all temperature sensors belonging to the - sub-group. In POWER9, this attribute corresponds to - each OCC. Using this attribute each OCC can be asked to - disable/enable all of its temperature sensors. - 1: Enable - 0: Disable - -inX_input Measured power supply voltage (millivolt) -inX_fault 0: No fail condition. - 1: Failing power supply. -inX_highest Historical maximum voltage -inX_lowest Historical minimum voltage -inX_enable Enable/disable all voltage sensors belonging to the - sub-group. In POWER9, this attribute corresponds to - each OCC. Using this attribute each OCC can be asked to - disable/enable all of its voltage sensors. - 1: Enable - 0: Disable - -powerX_input Power consumption (microWatt) -powerX_input_highest Historical maximum power -powerX_input_lowest Historical minimum power -powerX_enable Enable/disable all power sensors belonging to the - sub-group. In POWER9, this attribute corresponds to - each OCC. Using this attribute each OCC can be asked to - disable/enable all of its power sensors. - 1: Enable - 0: Disable - -currX_input Measured current (milliampere) -currX_highest Historical maximum current -currX_lowest Historical minimum current -currX_enable Enable/disable all current sensors belonging to the - sub-group. In POWER9, this attribute corresponds to - each OCC. Using this attribute each OCC can be asked to - disable/enable all of its current sensors. - 1: Enable - 0: Disable - -energyX_input Cumulative energy (microJoule) |