aboutsummaryrefslogtreecommitdiff
path: root/Documentation
diff options
context:
space:
mode:
authorLinus Torvalds <torvalds@linux-foundation.org>2015-09-11 16:13:47 -0700
committerLinus Torvalds <torvalds@linux-foundation.org>2015-09-11 16:13:47 -0700
commit9ebd051a7d5aa7b0ce813c3c2e5b9c851e7774b9 (patch)
tree5bc54f2de4312e5fe13356779c7bf49132e2a3fd /Documentation
parent51a73ba5f409ef6f419c8ec3a0d1257633500aaa (diff)
parent5a924a07f882e866f2337bf65048be357956691a (diff)
Merge branch 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux
Pull thermal updates from Zhang Rui: - use int instead of unsigned long to represent temperature to avoid bogus overheat detection when negative temperature reported. From Sascha Hauer. - export available thermal governors information to user space via sysfs. From Wei Ni. - introduce new thermal driver for Wildcat Point platform controller hub, which uses PCH thermal sensor and associated critical and hot trip points. From Tushar Dave. - add suuport for Intel Skylake and Denlow platforms in powerclamp driver. - some small cleanups in thermal core. * 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux: thermal: Add Intel PCH thermal driver thermal: Add comment explaining test for critical temperature thermal: Use IS_ENABLED instead of #ifdef thermal: remove unnecessary call to thermal_zone_device_set_polling thermal: trivial: fix typo in comment thermal: consistently use int for temperatures thermal: add available policies sysfs attribute thermal/powerclamp: add cpu id for denlow platform thermal/powerclamp: add cpu id for Skylake u/y thermal/powerclamp: add cpu id for skylake h/s
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/thermal/sysfs-api.txt6
1 files changed, 6 insertions, 0 deletions
diff --git a/Documentation/thermal/sysfs-api.txt b/Documentation/thermal/sysfs-api.txt
index c1f6864a8c5d..10f062ea6bc2 100644
--- a/Documentation/thermal/sysfs-api.txt
+++ b/Documentation/thermal/sysfs-api.txt
@@ -180,6 +180,7 @@ Thermal zone device sys I/F, created once it's registered:
|---temp: Current temperature
|---mode: Working mode of the thermal zone
|---policy: Thermal governor used for this zone
+ |---available_policies: Available thermal governors for this zone
|---trip_point_[0-*]_temp: Trip point temperature
|---trip_point_[0-*]_type: Trip point type
|---trip_point_[0-*]_hyst: Hysteresis value for this trip point
@@ -256,6 +257,10 @@ policy
One of the various thermal governors used for a particular zone.
RW, Required
+available_policies
+ Available thermal governors which can be used for a particular zone.
+ RO, Required
+
trip_point_[0-*]_temp
The temperature above which trip point will be fired.
Unit: millidegree Celsius
@@ -417,6 +422,7 @@ method, the sys I/F structure will be built like this:
|---temp: 37000
|---mode: enabled
|---policy: step_wise
+ |---available_policies: step_wise fair_share
|---trip_point_0_temp: 100000
|---trip_point_0_type: critical
|---trip_point_1_temp: 80000