diff --git a/drivers/hwmon/pmbus/Kconfig b/drivers/hwmon/pmbus/Kconfig
new file mode 100644
index 000000000000..c9237b9dcff2
--- /dev/null
+++ b/drivers/hwmon/pmbus/Kconfig
@@ -0,0 +1,100 @@
+#
+# PMBus chip drivers configuration
+#
+
+menuconfig PMBUS
+ tristate "PMBus support"
+ depends on I2C && EXPERIMENTAL
+ default n
+ help
+ Say yes here if you want to enable PMBus support.
+
+ This driver can also be built as a module. If so, the module will
+ be called pmbus_core.
+
+if PMBUS
+
+config SENSORS_PMBUS
+ tristate "Generic PMBus devices"
+ default y
+ help
+ If you say yes here you get hardware monitoring support for generic
+ PMBus devices, including but not limited to ADP4000, BMR450, BMR451,
+ BMR453, BMR454, LTC2978, NCP4200, and NCP4208.
+
+ This driver can also be built as a module. If so, the module will
+ be called pmbus.
+
+config SENSORS_ADM1275
+ tristate "Analog Devices ADM1275"
+ default n
+ help
+ If you say yes here you get hardware monitoring support for Analog
+ Devices ADM1275 Hot-Swap Controller and Digital Power Monitor.
+
+ This driver can also be built as a module. If so, the module will
+ be called adm1275.
+
+config SENSORS_LM25066
+ tristate "National Semiconductor LM25066 and compatibles"
+ default n
+ help
+ If you say yes here you get hardware monitoring support for National
+ Semiconductor LM25066, LM5064, and LM5066.
+
+ This driver can also be built as a module. If so, the module will
+ be called lm25066.
+
+config SENSORS_MAX16064
+ tristate "Maxim MAX16064"
+ default n
+ help
+ If you say yes here you get hardware monitoring support for Maxim
+ MAX16064.
+
+ This driver can also be built as a module. If so, the module will
+ be called max16064.
+
+config SENSORS_MAX34440
+ tristate "Maxim MAX34440/MAX34441"
+ default n
+ help
+ If you say yes here you get hardware monitoring support for Maxim
+ MAX34440 and MAX34441.
+
+ This driver can also be built as a module. If so, the module will
+ be called max34440.
+
+config SENSORS_MAX8688
+ tristate "Maxim MAX8688"
+ default n
+ help
+ If you say yes here you get hardware monitoring support for Maxim
+ MAX8688.
+
+ This driver can also be built as a module. If so, the module will
+ be called max8688.
+
+config SENSORS_UCD9000
+ tristate "TI UCD90120, UCD90124, UCD9090, UCD90910"
+ default n
+ help
+ If you say yes here you get hardware monitoring support for TI
+ UCD90120, UCD90124, UCD9090, UCD90910 Sequencer and System Health
+ Controllers.
+
+ This driver can also be built as a module. If so, the module will
+ be called ucd9000.
+
+config SENSORS_UCD9200
+ tristate "TI UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, UCD9248"
+ default n
+ help
+ If you say yes here you get hardware monitoring support for TI
+ UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, and UCD9248
+ Digital PWM System Controllers.
+
+ This driver can also be built as a module. If so, the module will
+ be called ucd9200.
+
+endif # PMBUS