hwmon: (lm90) Fix warnings
With some configuration option combinations, we get the following warnings: drivers/hwmon/lm90.c: In function 'lm90_detect': drivers/hwmon/lm90.c:1114: warning: 'chip_id' may be used uninitialized in this function drivers/hwmon/lm90.c:1114: warning: 'reg_config1' may be used uninitialized in this function drivers/hwmon/lm90.c:1114: warning: 'reg_convrate' may be used uninitialized in this function drivers/hwmon/lm90.c:1187: warning: 'reg_emerg2' may be used uninitialized in this function drivers/hwmon/lm90.c:1187: warning: 'reg_status2' may be used uninitialized in this function We can solve these easily by reading the register values first and checking for errors later. These errors should be very rare, even in the case of failed detection, so this change has no impact on performance. And this makes checkpatch.pl happier. Reported-by: Guenter Roeck <guenter.roeck@ericsson.com> Signed-off-by: Jean Delvare <khali@linux-fr.org> Acked-by: Guenter Roeck <guenter.roeck@ericsson.com>
Diffstat (limited to 'drivers/hwmon')
-rw-r--r--drivers/hwmon/lm90.c31
1 files changed, 16 insertions, 15 deletions
diff --git a/drivers/hwmon/lm90.c b/drivers/hwmon/lm90.c
index 90ddb8774210..60b3e3030277 100644
--- a/drivers/hwmon/lm90.c
+++ b/drivers/hwmon/lm90.c
@@ -1117,14 +1117,12 @@ static int lm90_detect(struct i2c_client *new_client,
return -ENODEV;
/* detection and identification */
- if ((man_id = i2c_smbus_read_byte_data(new_client,
- LM90_REG_R_MAN_ID)) < 0
- || (chip_id = i2c_smbus_read_byte_data(new_client,
- LM90_REG_R_CHIP_ID)) < 0
- || (reg_config1 = i2c_smbus_read_byte_data(new_client,
- LM90_REG_R_CONFIG1)) < 0
- || (reg_convrate = i2c_smbus_read_byte_data(new_client,
- LM90_REG_R_CONVRATE)) < 0)
+ man_id = i2c_smbus_read_byte_data(new_client, LM90_REG_R_MAN_ID);
+ chip_id = i2c_smbus_read_byte_data(new_client, LM90_REG_R_CHIP_ID);
+ reg_config1 = i2c_smbus_read_byte_data(new_client, LM90_REG_R_CONFIG1);
+ reg_convrate = i2c_smbus_read_byte_data(new_client,
+ LM90_REG_R_CONVRATE);
+ if (man_id < 0 || chip_id < 0 || reg_config1 < 0 || reg_convrate < 0)
return -ENODEV;
if (man_id == 0x01 || man_id == 0x5C || man_id == 0x41) {
@@ -1192,13 +1190,16 @@ static int lm90_detect(struct i2c_client *new_client,
* exists, both readings will reflect the same value. Otherwise,
* the readings will be different.
*/
- if ((reg_emerg = i2c_smbus_read_byte_data(new_client,
- MAX6659_REG_R_REMOTE_EMERG)) < 0
- || i2c_smbus_read_byte_data(new_client, LM90_REG_R_MAN_ID) < 0
- || (reg_emerg2 = i2c_smbus_read_byte_data(new_client,
- MAX6659_REG_R_REMOTE_EMERG)) < 0
- || (reg_status2 = i2c_smbus_read_byte_data(new_client,
- MAX6696_REG_R_STATUS2)) < 0)
+ reg_emerg = i2c_smbus_read_byte_data(new_client,
+ MAX6659_REG_R_REMOTE_EMERG);
+ man_id = i2c_smbus_read_byte_data(new_client,
+ LM90_REG_R_MAN_ID);
+ reg_emerg2 = i2c_smbus_read_byte_data(new_client,
+ MAX6659_REG_R_REMOTE_EMERG);
+ reg_status2 = i2c_smbus_read_byte_data(new_client,
+ MAX6696_REG_R_STATUS2);
+ if (reg_emerg < 0 || man_id < 0 || reg_emerg2 < 0
+ || reg_status2 < 0)