authorFrederic Barrat <fbarrat@linux.vnet.ibm.com>2016-06-17 18:53:28 +0200
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>2016-10-28 03:01:35 -0400
commitc346241e752ab9131689bce55d250ab2493ef952 (patch)
tree81900bd44c381d1d32a3070768a2a6606ab5d628 /arch/powerpc
parente382e130d45a9f95c8da77bc8bca1464ae9c6cae (diff)
powerpc/mm: Prevent unlikely crash in copro_calculate_slb()
commit d2cf909cda5f8c5609cb7ed6cda816c3e15528c7 upstream. If a cxl adapter faults on an invalid address for a kernel context, we may enter copro_calculate_slb() with a NULL mm pointer (kernel context) and an effective address which looks like a user address. Which will cause a crash when dereferencing mm. It is clearly an AFU bug, but there's no reason to crash either. So return an error, so that cxl can ack the interrupt with an address error. Fixes: 73d16a6e0e51 ("powerpc/cell: Move data segment faulting code out of cell platform") Signed-off-by: Frederic Barrat <fbarrat@linux.vnet.ibm.com> Acked-by: Ian Munsie <imunsie@au1.ibm.com> Signed-off-by: Michael Ellerman <mpe@ellerman.id.au> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Diffstat (limited to 'arch/powerpc')
-rw-r--r--arch/powerpc/mm/copro_fault.c2
1 files changed, 2 insertions, 0 deletions
diff --git a/arch/powerpc/mm/copro_fault.c b/arch/powerpc/mm/copro_fault.c
index 6527882ce05e..ddfd2740a1b5 100644
--- a/arch/powerpc/mm/copro_fault.c
+++ b/arch/powerpc/mm/copro_fault.c
@@ -106,6 +106,8 @@ int copro_calculate_slb(struct mm_struct *mm, u64 ea, struct copro_slb *slb)
switch (REGION_ID(ea)) {
case USER_REGION_ID:
pr_devel("%s: 0x%llx -- USER_REGION_ID\n", __func__, ea);
+ if (mm == NULL)
+ return 1;
psize = get_slice_psize(mm, ea);
ssize = user_segment_size(ea);
vsid = get_vsid(mm->context.id, ea, ssize);